NFP Premium
In order to remove the contamination of drinking water from the house pipes, such as lead or copper, we recommend using the NFP Premium drinking water cartridge. Due to its high performance spectrum in the event of possible drinking water contamination and its excellent hygienic properties, this filter cartridge is used in all CARBONIT® drinking water filters.
Service life:
The filter cartridge must be changed after 6 months (according to DIN 1988). In principle, 10,000 liters of water can be filtered within 6 months. However, an earlier change may be necessary if the water flow is noticeably reduced. An early change is not a defect in the filter used, but rather an indication of an increased occurrence of fine particles in the unfiltered water.
Filter fineness:
approx. 0.45 μm
Flow:
approx. 2 liters per minute (depending on water pressure)
Temperature:
Use only with cold water, protect from frost
parameter | reduction | Expert |
Escherichia coli1 Enterococcus faecalis1 | > 99.9>#/td### | GFT / Bielefeld University |
Lead2 Copper2 | > 90>#/td### | TÜV Environment |
Chlorine2 Chloroform2 Lindane2 DDT2 Atrazine2 | >99.0% >99.9% >99.8% >99.8% >99.8>#/p### | tti Magdeburg GmbH/FH Magdeburg |
Drug residues 2 - Clofibric acid - Carbamazepine - Diclofenac - Ikuprofen - Ketoprofen - Propiphenazone | >99.9% >99.9% >99.5% >99.9% >99.9% >99.9>#/p### | TU Berlin |
Polar pesticides2 - Bentazone - 2,4 D - Dichloroprop. - MCPA - Mecoprop. - pp'-DDA | >99.9% >99.9% >99.9% >99.9% >99.9% >99.5>#/p### | TU Berlin |
1 test with load over a period of use of 6 months 2 test with load over a filter capacity of 10,000 liters CARBONIT Monoblock NFP Premium filter cartridges are included as standard in the drinking water devices: SANUNO - VARIO - DUO The use in many commercially available standard housings is possible due to the standardized dimensions of the filter cartridge. A summary of the most important reports and much more information can be found at www.carbonit.com *) The GFT/Uni Bielefeld has also carried out tests for the following pathogenic germs. The retention rate was > 99.9% for all germs: Bacteria (Staphylococcus aureus, Staphylococus haemolyticus, Enterobacter cloacae, Pseudomonas aeruginosa, Bacillus subtilis) Microorganisms (Entamoeba coli, Giardia Lamblia, Cryptosporodium parvum, Hymenolepis nana, Schistosoma mansoni, Ascaris suum) Fungi/yeasts (Candida albicans, Rhodotorula mucilaginosa, Saccharomyces cerevisae) In addition, TÜV Rheinland/Berlin-Brandenburg confirmed that the results of the reports are reliable and sufficiently transferable to the actual use of the cartridge. Filters from CARBONIT: ALWAYS A GOOD CHOICE